Desktop|中文
Home About Us Products + News Center Technical Articles Messages Contact Us

Product Details

全自动Dielectric Loss Tester-扬州达瑞

Darry C-Type Rail - Yangzhou Darry Co., Ltd.

Published: 2020-08-11 09:36:57

Views: 2922

Category: ZT型悬挂滑轨滑车

Product Description


DarryC-Type Rail





Darry Electric recommends



Single-pole sliding contact line is a new type of power supply system for feeding power to mobile mechanical equipment. The conductor is made of high-quality aluminum alloy profile with special formula, and its outer protective sheath is made of special PVC material, which provides safety functions of rainproof, dustproof, snowproof, and electric shock prevention. It has a simple structure and is easy to install and maintain, and is widely used for power supply lines of mobile equipment in mines, metallurgy, chemical industry, machinery, docks, freight yards, etc. Features: 1. Safe and reliable, even if touched by fingers, there is no risk of electric shock, meeting IP23 standard. 2. Energy-saving and consumption-reducing, using special formula aluminum alloy profile as conductor; low resistance, can minimize power loss to the greatest extent. 3. Universal protective sheath and accessories. 4. The product complies with national standards JB6391.1-92 and JB6391.2-92. 5. Long service life, the conductor sheath also adopts a unique formula, greatly extending the service life of the single-pole sliding contact line system. 6. Adopts combined design, easy to install and maintain daily, especially suitable for high-altitude operations. 7. The current collector can move in three-dimensional space, meeting the uninterrupted power supply of power supply equipment; adopts double insulation design, making work safer and more reliable. 8. New materials, new technologies, and new processes ensure the product has higher corrosion resistance, acid resistance, weather resistance, and working temperature range, making its working performance safer and more reliable.



 



The installation of single-pole sliding contact line is relatively more flexible compared to other types of sliding contact lines. Here, I will briefly introduce the installation process of single-pole sliding contact line.



First, we need to select the fixed bracket. There are generally three types of fixed brackets for single-pole sliding contact lines, and of course, there are also some special models, which will not be exemplified here. The brackets are divided into I-shaped bracket, Z-shaped bracket, and L-shaped bracket. When selecting, it should be based on the model of the mobile equipment. For single-beam cranes, choose Z-shaped bracket; for double-beam cranes, choose I-shaped bracket. The selection of the bracket is generally determined by the model of the mobile equipment and the overall length of the sliding contact line, and can be adjusted appropriately by yourself. When installing the fixed brackets, keep the bracket horizontal and vertical and parallel to other installed fixed brackets. Generally, the installation distance of each fixed bracket is between 1.2M and 1.5M, which can be adjusted according to actual conditions. After the fixed brackets are installed, install the sliding contact line suspension frame on the fixed bracket, then put the single-pole sliding contact line into the suspension frame, and tighten the nuts on the suspension frame to fix it. Remember to install end caps at both ends of the sliding contact line.



Special attention: When the total length of a sliding contact line is greater than 150M-200M or when the sliding contact line works in a high-temperature environment for a long time, expansion sections must be installed. If multiple mobile devices run simultaneously on a single-pole sliding contact line, it is recommended to install maintenance sections, which make your inspection and maintenance more convenient. The installation position of the maintenance section is not fixed and can be adjusted according to your actual situation.



After completing the previous work, the only remaining step is to install the current collector. We just need to fix the current collector to the mobile equipment through the bracket, so that the current collector can run flexibly within the sliding contact line track. After the current collector is installed, the entire single-pole sliding contact line is installed. Then, after a final check, we can turn on the power and conduct a trial run, starting from equipment with small power to large power, to check whether all links are safe and error-free.







Note: The above information and technical parameters are compiled and released by Yangzhou Darry Electric Co., Ltd.



 


WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us